527 resultados para Coaxial cables


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper demonstrates a novel digital radio distribution system able to transmit not only over optical fibres and coaxial cables but also over twisted pair cables. The digitised RF signal is compressed for maximum transmission efficiency in a way that allows for integral self-learning algorithms to be introduced for multi-service applications. © 2013 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new quadrifilar antenna has been developed for generating circularly polarized backfire radiation. The antenna consists of two orthogonal rectangular conducting loops, each incorporating capacitive coupling and fed using either a single or two coaxial cables. Though the geometry is much simpler than a conventional quadrifilar helix antenna, the radiation pattern performance is very similar. Measured and simulated patterns are compared for two antennas with different feed arrangements. It is shown that the resonant structure can produce a cardioid pattern with a directivity of 4.5 dB (120 3-dB beamwidth) and a front-to-back ratio of more than 20 dB at the center operating frequency. A 10% impedance bandwidth (VSWR

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Different measurements were performed in cross-linked polyethylene (XLPE) employed as insulating material in coaxial cables that were field-aged and laboratory-aged under multi-stressing conditions at room temperature. Samples were peeled from the XLPE cable insulation in three different positions: just below the external semiconductor layer (outer layer), in the middle (middle layer) and just above the internal semiconductor layer of the cable (inner layer). The imaginary part of the electric susceptibility showed three peaks that obey the Dissado-Hill model. For laboratory-aged XLPE samples peeled from the inner and from the middle positions the peak at very low frequency region increased while in samples from the outer position a quasi-DC conduction process was observed. In medium frequency range a broadening of the peak was observed for all samples. Viscoelastic properties determined through dynamic mechanical analysis suggested that the aging generates processes that promoted changes of the crystallinity and the cross-linking degrees of the polymer. Fourier transform infrared spectroscopy (FTIR) measurements revealed an increase of oxidation products (esters), evidence of polar residues of the bow-tie tree and the presence of cross-linking by-products (acetophenone). Optical and scanning electronic microscope (SEM) measurements in aged samples revealed the existence of voids and bow-tie trees that were formed during aging in the middle region of the cable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we present an analysis that shows the Maxwell Fish Eye (MFE) only has super-resolution property for some particular frequencies (for other frequencies, the MFE behaves as conventional imaging lens). These frequencies are directly connected with the Schumann resonance frequencies of spherical symmetric systems. The analysis have been done using a thin spherical waveguide (two concentric spheres with constant index between them), which is a dual form of the MFE (the electrical fields in the MFE can be mapped into the radial electrical fields in the spherical waveguide). In the spherical waveguide the fields are guided inside the space between the concentric spheres. A microwave circuit comprising three elements: the spherical waveguide, the source and the receiver (two coaxial cables) is designed in COMSOL. The super-resolution is demonstrated by calculation of Scaterring (S) parameters for different position of the coaxial cables and different frequencies of the input signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dispersion properties and topography of the fields of azimuthal surface wave (ASW) in a coaxial semiconductor structure with metal walls, placed in an external magnetic field, are investigated analytically and numerically. It is shown that an ASW phase-shifting device can be realized in the proposed structure. The conditions are indicated for which wave perturbations exist having frequencies that depend on the direction of phase change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modal flexibility is a widely accepted technique to detect structural damage using vibration characteristics. Its application to detect damage in long span large diameter cables such as those used in suspension bridge main cables has not received much attention. This paper uses the modal flexibility method incorporating two damage indices (DIs) based on lateral and vertical modes to localize damage in such cables. The competency of those DIs in damage detection is tested by the numerically obtained vibration characteristics of a suspended cable in both intact and damaged states. Three single damage cases and one multiple damage case are considered. The impact of random measurement noise in the modal data on the damage localization capability of these two DIs is next examined. Long span large diameter cables are characterized by the two critical cable parameters named bending stiffness and sag-extensibility. The influence of these parameters in the damage localization capability of the two DIs is evaluated by a parametric study with two single damage cases. Results confirm that the damage index based on lateral vibration modes has the ability to successfully detect and locate damage in suspended cables with 5% noise in modal data for a range of cable parameters. This simple approach therefore can be extended for timely damage detection in cables of suspension bridges and thereby enhance their service during their life spans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study is made on the flow and heat transfer of a viscous fluid confined between two parallel disks. The disks are allowed to rotate with different time dependent angular velocities, and the upper disk is made to approach the lower one with a constant speed. Numerical solutions of the governing parabolic partial differential equations are obtained through a fourth-order accurate compact finite difference scheme. The normal forces and torques that the fluid exerts on the rotating surfaces are obtained at different nondimensional times for different values of the rate of squeezing and disk angular velocities. The temperature distribution and heat transfer are also investigated in the present analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental results for breakdown voltage of sodium vapour measured for the first time using coaxial cylindrical electrodes of fixed gap distance (5 mm) and pressure (corrected to2 0 "C) in the range2 1 to 652 Pa are reported, and are founfdo l ltoow Paschen's Law. The investigations also reveal that V th-Ie characteristics are pressure dependent; the current during the breakdown and the buoifl dc-uurpre nt after a breakdoiws nei ther positive or negative. in spite of the central cylinder being always maintained at a positive potential

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The firing and delay characteristics of a simple coaxial type of triggered vacuum gap (TVG) are described and compared with the planar type. The designs are new and differ from those reported earlier. By analogy with gaseous breakdown the statistical and formative time lags have been determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the case of an ac cable, power transmission is limited by the length of the cable due to the capacitive reactive current component. It is well known that high-voltage direct current (HVDC) cables do not have such limitations. However, insulation-related thermal problems pose a limitation on the power capability of HVDC cables. The author presents a viable theoretical development, a logical extension to Whitehead's theory on thermal limitations of the insulation. The computation of the maximum power-carrying capability of HVDC cables subject to limits on the maximum operable temperature of the insulation is presented. The limitation on the power-carrying capability is closely associated with the electrothermal insulation failure. The effect of environmental interaction by way of external thermal resistance, an important aspect, is also considered in the formulations. The Lagrange multiplier method has been used to handle the ensuing optimization problem. The theory is based on an accepted theory of thermal breakdown in insulation and is an important and a coherent extension of great significance.